Mitsubishi FX series PLC programming cable USB-SC09-FX driver cannot be installed
you can use this usb sc09 driver
The difference between USB-ppi and pc-ppi
Siemens s7-200 programming line USB-ppi and communication line pc-ppi need to be purchased separately. Why can't the programming line be used directly for communication? Overview: USB / PPI is a programming cable that provides serial connection and RS485 signal conversion and PPI protocol conversion through a USB interface. Under the control of a driver running … Continue reading The difference between USB-ppi and pc-ppi
LE3U PLC Test video and plc program example
LE3U PLC Support Mitsubishi GX-Develoer\GX-WORK2 Support for human-machine interface connection, the application is completely equivalent to Mitsubishi FX3U Support ladder programming, download, monitoring. The programming port used for program download and communication with the human machine This PLC adopts an industrial-grade 32-bit MCU with strong anti-interference, and its running speed far exceeds that of FX3U. … Continue reading LE3U PLC Test video and plc program example
USB-SC09-fx detailed usage guide
The USB-SC09-FX programming cable requires a USB device driver to be used After the driver installation is complete, the COM port corresponding to the USB-SC09-FX programming cable will appear in the Windows device manager. Just select the COM port in the programming software or other application software, and use the default settings for other communication … Continue reading USB-SC09-fx detailed usage guide
AMSAMOTION cable driver installation tutorial
1. Put your driver CD into the computer and plug the cable into the USB port of the computer. Double-click the AMSAMOTION.EXE program and the following screen will appear. 2. Click it. When the following display appears, congratulations, your driver has been successfully installed! 3. At this time, return to the "Device Manager" of your … Continue reading AMSAMOTION cable driver installation tutorial
Mitsubishi PLC PLSY instruction
PLSY: 16-bit continuous execution type pulse output command DPLSY: 32-bit continuous execution type pulse output command. Programming format of FXPLC PLSY instruction: PLSY K1000 D0 Y0 K1000: The specified output pulse frequency, which can be T, C, D, value or a combination of bit components such as K4X0. D0: The specified number of output pulses, … Continue reading Mitsubishi PLC PLSY instruction
Mitsubishi PLC “ALT” instruction
ALT instruction is alternate output Assume that Y0 is the indicator light. LDP X0 ALT Y0 At this time, Y0 is off, and when X0 is pressed, the indicator lights up. Press again to turn off the light, then press again to light. It's as simple as that, it will alternate output. This can also … Continue reading Mitsubishi PLC “ALT” instruction
The specific usage of the comparison instructions in Mitsubishi Plc
The comparison instructions in Mitsubishi Plc are divided into CMP and ZCP. 1. The instruction code of CMP is FNC10, the instruction code of ZCP is FNC11, and the source operands [S·] to be compared are K, H, KnX, KnY, KnM, KnS, T, C, D, V, Z, its target operand [D·] is Y, M, S. … Continue reading The specific usage of the comparison instructions in Mitsubishi Plc
Mitsubishi PLC INC D125
M8000 is a constant ON address. The whole statement means that the program scans every time from start to finish. When it reaches this statement, D125 will add 1 and the maximum will be added to 65535. Because INC is 16 is a self-addition instruction. This statement can be used to see how many cycles … Continue reading Mitsubishi PLC INC D125