PLC programming is based on the hardware system. Different hardware systems have different processing behaviors. If the programming is not rigorous, it will cause deviations in the results. Therefore, programming must be standardized. The advantage of standardization is that these deviations can be avoided. At the same time, the standardization of programming is also standardized. … Continue reading The same program has different responses in different PLCs
Category: plc program
PROFINET_IO Vs RT
Profinet can be understood as a relatively special highway (such as the highway I saw in Indonesia), which is divided into three lanes: passing lane, driving lane, motorcycle lane… Then we often see Profinet IRT, Profinet RT corresponds to passing lanes and driving lanes. In addition, the Profinet we are talking about also has a … Continue reading PROFINET_IO Vs RT
kinco hmi mt4434t
MT4434t man-machine interface, with LINUX kernel, high-speed CPU, faster communication speed, and smoother screen operation. It is worth mentioning that the LED backlight can be adjusted, so as to protect the environment. MT4434T softwere is Kinco HMIware is free.
real time clock accuracy in s7 200 (siemens)plc
HOW MUCH REAL TIME CLOCK ACCURACY IN S7 200 (SIEMENS)PLC ? S7-200 real-time clock The hardware real-time clock of S7-200 can provide date/time data of year, month, hour, minute and second. CPU221 and CPU222 do not have a built-in real-time clock, and an external "clock/battery card" is needed to obtain this function. CPU224, CPU226 and … Continue reading real time clock accuracy in s7 200 (siemens)plc
How to upload program to PLC of twido series?
In twidosoft software, if there is no program protection setting in the program, you can upload the program in the PLC.Only when the PLC is online, click the "Connect" option in the "Controller" menu in the software. At this time, an option box will appear. Click the "Controller to PC" option directly to upload the … Continue reading How to upload program to PLC of twido series?
1747-UIC configuration
Plug in the 1747-UIC adapter of the USB port, install the 1747-UIC hardware driver according to the manual, it is best to use it under XP SP2, and the driver of the USB DH-485 Serial port COM3 (USB to virtual serial port) is displayed in the device manager It is normal, no need to reinstall … Continue reading 1747-UIC configuration
6es7 972-0cb20-0xa0 driver installation
USB MPI DRIVER Use 6ES7 972-0CB20-0XA0 (PC ADAPTER USB) to download the s7-300 / 400 plc program, but the driver cannot be install? Solution: Download PC Adapt USB driver file Find the driver file and copy it to: C: \ Program Files \ Common Files \ Siemens \ Automation \ Simatic OAM \ DriversThen open “Device Manager”, select “SIMATIC … Continue reading 6es7 972-0cb20-0xa0 driver installation
Mitsubishi GOT1050 QBBD software
Mitsubishi GOT1050 QBBD HMI can use GT Designer2 software GOT1050 QBBD cable is GT01-C30R4-8P
IAI RCM-101-USB
RCM-101-USB is the ACON / PCON / SCON debug cable data cable here is IAI RCM-101-USB cable driver
Mitsubishi PLC and Weinview MT6070iH touch screen cable
WeinView MT8000 interfaceseries CPUMITSUBISHI PLC FXCOM1 [RS485] 4w 9-pin D-shaped portRS422 port 8-pin Din round port1 RX-4 TX-2 RX+7 TX+3 TX-1 RX-4 TX+2 RX+5 GND3 GND Weinview MT6000,MT8000 Series Touch pannel connect Mitsubishi FX series PLC communication cable