CNC 4 AXIS OFFLINE CONTROLLER BREAKOUT BOARD ENGRAVING MACHINE CONTROL SYSTEM CARD WHY this controller is so appealing? - Control machine by this controller without computer. Specification: Model Number SMC4-4-16A16B HZ 50KHZ Axis 4 Axis, X Y Z A CPU 32 Memory 2GB LCD 320*240 Size 165*101*50mm Language English Application CNC Engraving machine and CNC … Continue reading SMC4-4-16A16B Offline CNC Controller
Category: plc program
How does the TK6070IP use EB8000 software to convert to TK6071IP using EBpro software?
When the new product is introduced, Weilun touch screen has taken into account various factors of HMI upgrade and replacement, and strives to facilitate the use of HMI for customers. Here, from software operation instructions, USB programming port, communication port, power isolation protection, installation Different aspects of the way, explain the similarities and differences of … Continue reading How does the TK6070IP use EB8000 software to convert to TK6071IP using EBpro software?
Mitsubishi PLC temperature control ladder diagram example
A program PID control with temperature control at 35 degrees
Mitsubishi PLC controls the forward and reverse ladder of the motor
X0----forward rotation X1----reverse start X2----stop Y0----forward running Y1---- reverse running T0----forward rotation stop delay T1----reverse stop delay
How to input read analog in Mitsubishi PLC ladder diagram
About the SUB and MUL instructions in Mitsubishi PLC ladder diagram
How to program Mitsubishi PLC time relay in ladder diagram
Input OUT T1 K10 directly in the software, where T1 is the time relay number, K is followed by the time value, in decimal
OP320 – A 3.7 inch Text Display HMI Support S485/RS232 Communication Port Mainly Used with PLC
❤【Introduction】- OP320-A is a small man-machine interface, mainly used with various kinds of PLC (or intelligent controller with communication port) ❤【Function】- Communication protocol and screen data are downloaded to the display without PLC writing communication program. It has password protection, has alarm list function, line by line real-time display current alarm information. With background light … Continue reading OP320 – A 3.7 inch Text Display HMI Support S485/RS232 Communication Port Mainly Used with PLC
Mitsubishi PLC command CMP
CMP is a comparison instruction for 16-bit data comparison. The comparison data range is -32768 to +32767. The comparison data type can be Changshu K, H, etc. It can be data register D or counter C. It can be a time relay. T, can also be a continuous address (such as K1X0, K2Y0, K3M0, K2S0, … Continue reading Mitsubishi PLC command CMP
Mitsubishi plc programming Bit component transfer
With the transfer instruction, For example, MOV k1x0 k1y0, k1 represents 4 bits (x0--x3), k2 is 8 bits (xo--x7), k3 is 12 bits, k4 is 16 bits, and x and y are the same. For example, x3--x0 is 1001, and y 3 --- y0 are 1, 0, 0, and 1, respectively. The same principle