Plc Transistor output vs Relay output1. Different load voltage and current typesLoad type: The transistor can only have a DC load, and the relay can be used with both AC and DC loads.Current: Transistor current 0.2A-0.3A, relay 2A.Voltage: The transistor can be connected to DC 24V (generally the maximum is about 30V DC, the relay … Continue reading plc transistor output vs relay output
Category: plc program
How is the Siemens PLCs7-200 connected to the encoder for measuring position?
Defining a high-speed counter is nothing more than the following steps:1. Create an initialization program, controlled by SM0.1;2. Initialize the high-speed counter in the initialization program2.1 Set the control register (HSC0 is SMB37), different counters correspond to different DI points, HSC0 is I0.0, HSC3 is I0.1, HSC4 is I0.2, HSC5 is I0.3 (222 does not … Continue reading How is the Siemens PLCs7-200 connected to the encoder for measuring position?
Delta plc and encoder connection
Delta's EH series PLC has a set of high-speed counter inputs, X0, X1, X2, X3.Use C251 two-phase two inputs X1=A, X2=B,At C252, X0=A, X1=B, X2=RX253=A, X1=B, X2=R, X3=S at C253A=A phase, B=B phase, R=reset, S=startJust connect the line and write the counter program directly.X10 is reset and X11 is active. (X0, X1 need not be … Continue reading Delta plc and encoder connection
Mitsubishi FX series PLC counter application ladder diagram example
Counter Plc ladder DiagramNote: X3 resets the counter C0, C0 counts the pulse input to X4, the number of input pulses reaches 6, the normally open contact of counter C0 is closed, and Y0 is energized. When X3 is active, C0 is reset and Y0 is de-energized.
top cnc controller topcnc brand
TOP CNC Controller1,TC55H TOPCNC CNC controllerTC55H manual1. Product IntroductionTC55H is an upgrading version of TC55. It can control 4 feeding axis, 1 analog spindle. It is equipped with 16 input port and 8 output port, supporting importing G code files from USB stick. Support saving the current coordinates after power off. 2. Technical Specifications Minimum data unit 0.001 mmMaximum data size ± 99999.999mmMaximum Speed: 24m/min (pulse is 0.001mm)Maximum pulse output frequency 400KHzAxis 1-4 (X,Y, Z,C)X,Y,Z,C axis can conduct linear interpolation, X,Y can do circular interpolation. Electric Gear: numerator :1-99999 denominator: 1-99999 USB: Importing program and boot picture(You can load your own logo)Isolated I/O portMaximum Program Line:1000Maximum Program: 99RAM: 128MExternal Manual Operation: motor clockwise and counter clockwise spinning, start, pause, alert and stop G code and M codeOne panel MPG(Registered Patent)3.5 inch color LCD, pixel 320*240 Analog Spindle Output: one 0-10v analog spindleSupport both servo and stepper motor Support metric system, round, division, degree, inch etcUse a usb to connect the computer as power supply or 24VDC power We are producer of this controller, so we … Continue reading top cnc controller topcnc brand
SMC5-5-N-N DSP Offline CNC Controller 5 Axis
DSP controller SMC5-5-N-N CNC Controller for milling machine SMC5-5-N-N CNC Controller Manual Related video SMC5-5-N-N 5 axis off-line controller Offline CNC controller SMC5-5-N-N 5 axis off-line controller Offline CNC controller-2 SMC5-5-N-N 5 axis off-line controller Offline CNC controller-3 CNC 5 Axis Motion Controller Offline CNC Controller 500KHz Replace Mach 3 USB Motion Controller 7inch Screen … Continue reading SMC5-5-N-N DSP Offline CNC Controller 5 Axis
GX Developer timer command
Timer T is the timer symbol, 0 is the number, K is the constant, it is decimal, that is, it is one second when it is set to K10. The value oh D212 acts as the K value. Typically done when you want to allow a timer to be changed without accessing the program (from … Continue reading GX Developer timer command
What is the command of Mitsubishi PLC [DDRVI K99999 K8000 Y0 Y03]
DDRVI instructionDRVI is a relative positioning instruction (DRVI is 16 bits, DDRVI is 32 bits), and the current data in the current value register is used as a starting point to increase or decrease. It is a command to perform single speed position control in relative drive mode.DDRVI K99999 K8000 Y0 Y03Output pulse number Output … Continue reading What is the command of Mitsubishi PLC [DDRVI K99999 K8000 Y0 Y03]
The scan cycle of the PLC, what is the scan cycle of the PLC?
When the PLC is in the RUN mode, the time required to perform a scan operation is called the scan period, and its typical value is about 1 to 100 ms.The plc scan cycle has a lot to do with the length of the user program, the type of instructions, and the speed at which … Continue reading The scan cycle of the PLC, what is the scan cycle of the PLC?
High-speed counter (HSC) of Mitsubishi FX series PLC
1. High speed counterThe 21-point high-speed counters C235 to C255 share the eight high-speed counter input terminals X0 to X7 of the PLC, and one input terminal can only be used for one high-speed counter at the same time. These 21 counters are all 32-bit up/down counters (see Table 3–7). Different types of high-speed counters … Continue reading High-speed counter (HSC) of Mitsubishi FX series PLC







![What is the command of Mitsubishi PLC [DDRVI K99999 K8000 Y0 Y03]](https://plchomeblog.files.wordpress.com/2018/10/a26df-20181012154559.jpg?w=656&h=300&crop=1)