Wincc7.0 SP1 when you deactivate "alarm system" stuck not moving1. project integration2. the path of Chinese characters3. alarm: configuration operator recordsTwo. OS project editor: Select message configuration and complete configuration only difference?The best answerYou have I encountered this situation, there was an acceptance of the WINCC project, but now I want to use OS project … Continue reading SP1 wincc7.0 stuck
Category: plc program
CP341 hangs on ET200M, how to software distribution?
Now in a redundant system, CPU414-4H ET200M module using PROFIBUS communication, but need to use Modbus communication, I can see document said ET200M CP341 Modbus master, then practice again to field devices, hardware configuration was introduced, but at the time of software, still called the FC functions directly?The best answerUse consistent and in 300.CP341 PTP … Continue reading CP341 hangs on ET200M, how to software distribution?
How to use CPU224XP to control the bar code printer and scanning gun
Use CPU224XP control bar code printer and scanner, and requires induction to a product, PLC automatically generates an automatic increase bar code and automatically check for the right bar code scanner, what should I do, what hardware it needs backgroundThe best answerFirst of all you need 2 communication ports do free traffic and bar code … Continue reading How to use CPU224XP to control the bar code printer and scanning gun
Can the WINCC6,0 system be shared with a BA monitoring system on a computer?
Used to be 2 computers, a DDC system control computer, a PLC and is related withWINCC6.0 computer, BA monitor computer access communication through OPC Protocol; now combined in one computer, can achieve? Will there be conflict database?Also, WINCC6.0 as the server, can be more than one computer at the same time as the client access?The … Continue reading Can the WINCC6,0 system be shared with a BA monitoring system on a computer?
3TK2983-0BB4 product manual
Getting 3TK2983-0BB4 product brochures,The best answerTo look at here:http://support.automation.siemens.com/WW/llisapi.dll?func=ll&objId=22926038&nodeid0=20358221&prodLstObjId=22926038&subtype=133400&lang=de&siteid=cseus&aktprim=0& objaction=csviewtd&extranet=standard&viewreg=WW&selectedLang;22926038=1&switchLang;22926038;6.x=1&langex=zh
how to SIEMENS 300PLC connect with the servo motor
Companies have been using the Siemens 300PLC a connection before Mitsubishi servo motor. I 300PLC put the FM module. Servo servo controller. Because we are theowners of reason. Not the manufacturer. At that time I was responsible for some simple maintenance and troubleshooting. What are other people doing. But I feel that I still do … Continue reading how to SIEMENS 300PLC connect with the servo motor
How to use the 300plc as master and 200PLC as slave station of DP group
Using a 300plc CPU 314C-2DP now call the shots and do 3 sets of 200plc CPU is 226DP network from a station group. DP communication module uses EM277. now have a problem, when I try with a 200plc network, there is no problem, but not more than two. I configured the hardware download into 300plc … Continue reading How to use the 300plc as master and 200PLC as slave station of DP group
How to communicate MPI line with MPI port
CP5711 with MPI cable plug in MPI, PG/PC automatically State, the properties startnetwork detection connection into a DP can detect communication. Then a DP lineconnecting 5711 with the MPI port, test, ask why? MPI line DP 4 more than 5 feet, are here for a reason. Venue is the desk.Supplementary question:PG/PC select 5711 automatic State, … Continue reading How to communicate MPI line with MPI port
How to rewrite before upload TP270-10 touch screen
Touch-screen TP270-10 backup file in PSD format what software do I use to rewriteWINCC2008 read-only can be converted to HMI HMI format PSD format file formathow do you rewrite TP270 touch-screen uploaded backSupplementary question:New editors can do WINCC2008 written with WINCC HMI HMI format is the formatcan do what to touch-screen communicationThe best answerPSD-format file … Continue reading How to rewrite before upload TP270-10 touch screen
How to rewrite the TP270-10 touch-screen file backup
Now Wincc2008B version but only read out touch-screen HMI format files are PSD format from touch-screen of the PSD file format how to rewrite and then pass into the touch screen now only backup to restore in the touch-screen how to change outThe best answerOnly install the touch screen SD card and return is enabled … Continue reading How to rewrite the TP270-10 touch-screen file backup