S7-300 hardware configuration and module power consumption calculation method

Using S7300 313C CPU plus IM365 extended a frame of.313C comes with its own 24DI16DO and 5AI/2AO analog input and output, see the manual configuration above CPU can be placed behind the 8 modules, would like to ask, CPU integrated I/O surface to exclude? No matter what CPU can be placed back 8 modules (on … Continue reading S7-300 hardware configuration and module power consumption calculation method

DP network flash jump – how to diagnose system

These days with DP network jump problem: should be a few remote IO station off the station after a very short period of time to recover automatically, because these IO security module on the station, so will lead to part of the emergency shutdown, and from the perspective of diagnostic information (multi 16#3942 16#3842), the … Continue reading DP network flash jump – how to diagnose system

How to use a computer to achieve the same time on the two PLC access?

Recently the communication between two PLC, if you use SIEMENS's own words each cable programming procedure is very troublesome, for which a PLC after pulling down into another PLC again under the corresponding procedures, and online modify variable values and also not easy, so I would like to ask how to at the same time … Continue reading How to use a computer to achieve the same time on the two PLC access?

300plc master and 200PLC as slave station group DP network related issues

A 300PLC CPU 314C-2DP the master station and three sets of 200plc CPU 226 DP network from a station group, communication module is EM277. Preliminary 300plc and 200plc Group DP network hardware is configured to download properly, but when more than two 200plc network, after downloaded into 300 (OB blocks without programming, hardware configuration only) … Continue reading 300plc master and 200PLC as slave station group DP network related issues

CPU224xp in the running state, switching back and forth in RUN and STOP What is going on

CPU224xp to run, RUN and STOP switch back and forth, re-download and then well,don't know whether this is the case.The best answerYou mean your PLC running times before failure, and when machine is it? If this is the case, even if you are normal, there will still be a problem in the future.Because is now … Continue reading CPU224xp in the running state, switching back and forth in RUN and STOP What is going on

SMART PLC S7-200 communication portal common knowledge to answer

1th: communication is what?Essentially communication ports around the combination of high and low level, to achieve 0 1 codes delivered between two devices, 0 is low level, 1 is high. Now, if I have a PLC and inverter communication, then the fact is hardware and cables throughthe communications port of the inverter produces combinations of … Continue reading SMART PLC S7-200 communication portal common knowledge to answer

Five standard programming languages for PLC

PLC user program is designed according to the process control requirements of the control system, the design of the PLC programming language. Industrial control programming language standard (IEC1131-3) based on the international electric commission. PLC programming language includes the following five kinds: ladder diagram language (LD), instruction list language (IL), function module diagram language (FBD), … Continue reading Five standard programming languages for PLC