Can, in general, the drive can be controlled in various ways, such as using analog output control inverter, OMRON CQM1H or use the protocol macro function of the inverter communication control, but requires the drive belt 422/485 communications port, If the drive supports DEVICENET protocol, it can also be linked directly into our COMPOBUS / … Continue reading How do Omron CQM1H and Delta inverter communication
Category: plc program
Omron CQM1H series PLC, the memory card with the ability to backup DM data area of the data?
No, Omron PLC CQM1H series of its memory card can only backup program, DM (read-only data and PC settings) and extended instructions. If CJ1 series PLC can back up data DM data area.
PID module And PID instructions Which is better
PID instruction does not require PID hardware, it simply AD / DA input and output, but it takes up the PLC scan cycle; directly PID modules, without AD / DA's, and basically do not take up the scan cycle, but the need to invest in hardware costs, users are advised to consider the economic situation … Continue reading PID module And PID instructions Which is better
Omron PLC Failure Analysis and Troubleshooting
1, Q: What kind of floating-point advantage in the result of the operation, he is not a small point and carry bit? Floating point and double precision floating point, what kind of difference?A: decimal floating point arithmetic with support, which is its advantage, floating-point operations per participation operations accounted for two-channel and double precision floating … Continue reading Omron PLC Failure Analysis and Troubleshooting
Omron PLC and temperature meter 485 serial communication realization
Omron PLC and other instruments or communications equipment (whether OMRON instruments or third-party instrumentation), with the use of serial communication protocol macro module or template, for the corresponding procedures according to the instrument or device communication protocol, establish the appropriate communication channel, it the instrument can read and write. I worked with third-party customers for over-temperature … Continue reading Omron PLC and temperature meter 485 serial communication realization
plc ladder switch tricks
PLC ladder, made to enter an inverted trapezoid, which is to complex, simple post, here is an inverted trapezoid diagram: The output is made positive trapezoid that briefly after complex. Writing good ladder, we must follow the above principles, the review does not meet the changes. First, draw the conventional logic circuit diagram, and then facing compile … Continue reading plc ladder switch tricks
Omron CP1 series PLC high-speed counter current value of how to maintain power?
Save power by PV PRV read to D, use INI instruction change PV power function, the D area data assignment back to PV. (Note: After the power failure, to ensure that the encoder does not rotate, otherwise the amount of rotation of the pulse will be lost).To maintain the high-speed counter 0 PV value
Omron CPM1A series PLC programming cable made method
Omron PLC and Siemens touch screen Communication setting method
OMRON PLC can not communicate with TP177B / DP touch screen, But TP177A / DP and other communication with the screen (have repeatedly tested)Specific settings Communication Notes:(1) All communication settings (HMI and PLC) must be consistent (station number, baud rate, parity, etc., Use the default values here namely: "9600,7, Even / even, 2");(2) CPU-42H 4 feet should … Continue reading Omron PLC and Siemens touch screen Communication setting method
Omron PLC high-speed counter reset method
Omron PLC high-speed counting the number of reset mode, choose Z signal + software reset and soft reset in two ways. 1. Z signal + software reset mode High-speed counter reset flag is ON state, Z-phase signal and reset input OFF → ON time by the high-speed counter current value is reset. The case of … Continue reading Omron PLC high-speed counter reset method