Siemens S7-300/400 PLC Closed-loop control module

1, FM 355 closed-loop control module FM 355 closed-loop control channel 4, used for pressure, flow, liquid level control, optimum temperature control and PID algorithms. FM 355C analog output is 4 fracture of continuous controller, FM 355 s is 8 digital output point step controllers or pulse. CPU FM 355 people after a disruption or failure … Continue reading Siemens S7-300/400 PLC Closed-loop control module

Siemens new PLC program, data storage cards

MMC card is the new Siemens PLC program, data storage, and present several PLC should be used for the following products:Order product name6ES7 314-1AF10-0AB0 new CPU 3146ES7 new CPU 315-2AG10-0AB0 315-2DP6ES7 312-5BD00-0AB0 CPU 312C6ES7 313-5BE00-0AB0 CPU 313C6ES7 313-6CE00-0AB0 CPU 313C-2DP6ES7 313-6BE00-0AB0 CPU 313C-2PTP6ES7 314-6CF00-0AB0 CPU 314C-2DP6ES7 314-6BF00-0AB0 CPU 314C-2PTP6ES7 613-1CA00-0AE3 C7 6136ES7 635-2EC00-0AE3 C7 635 … Continue reading Siemens new PLC program, data storage cards

EM235 module DIP switches selection

  1, switch 6 on/off button to divide the table into two States unipolar/bipolar two full scale input. SW6=ON, select the unipolar; SW6=OFF, select dual polarity.2, switches 4 and 5 Select gain. SW4 and SW5 3 combinations, namely SW4=ON,SW5=OFF;SW4= OFF,SW5=ON;SW4= OFF,SW5=OFF. A case study of unipolar, when SW4=ON,SW5=OFF, full scale input 0 to 50mV,0 to 100mV … Continue reading EM235 module DIP switches selection

Siemens 200 PLC analog input/output

Analog input/output universal conversion formula you can use the following conversion:Ov = [(Osh - Osl)*(Iv - Isl)/(Ish - Isl)] + OslOf which:Ov: conversion resultsIv: conversion objectsOsh: conversion result limitOsl: conversion results lower limitIsh: conversion limitIsl: conversion of lower limitSTEP 7-Micro/WIN Programming Tips (Micro/WIN programming skills) Tip38 about how to achieve the conversion routines.For convenience of … Continue reading Siemens 200 PLC analog input/output

Siemens PLC analog module usage questions

S7-200 analog input module (EM231,EM235) addressingEach analog expansion module, sorted by extension modules in the order, in which the analog input and output according to different sorting, respectively. Analog data format is one word, so the address must begin with an even number of bytes, precision 12-bit; analog values with the value 0-32000. Input format: … Continue reading Siemens PLC analog module usage questions

The difference between Siemens PLC and S7-300 S7-200, S7-400

The main class is one of the programmable logic controller and module difference was S7-200 belonging to the basic entry level, while S7-300 and S7-400 relative to the use of higher-end. Siemens plc is the serial number of the product.---->S7 200: in the electric control system for small, focused on logical control;---->S7 300: for larger … Continue reading The difference between Siemens PLC and S7-300 S7-200, S7-400