Through the program determines the touch screen and plc communication failure method

The usual method is to use heartbeat, defined a bool, HMI fixed point set the frequency, PLC receives the point after ON signal is reset. If a period of time, for example, do not receive the points for the ON signal within 5s, it is considered Tongxu interrupted.plc to the memory clock of bytes transmitted … Continue reading Through the program determines the touch screen and plc communication failure method

PLC program sequential logic design method

(1) overview Sequential logic design method is suitable for the output signals of the status change of the PLC has some chronological situation, when in programming according to draw sequence diagram of the output signal, streamlining the state transitions and transition conditions, examine the output and input and internal contacts and the relationship, and make the … Continue reading PLC program sequential logic design method

PLC program Transplantation Design Method Programming steps

(1) the analysis of the existing system worksUnderstand the process of the controlled device and mechanical functioning, according to relay diagram analysis and principle of master control system. (2) PLC I/O distributionDetermine the system's input and output devices, the PLC I/O allocation, draw the PLC wiring diagram. (3) correspond to the establishment of other componentsOK relay diagram … Continue reading PLC program Transplantation Design Method Programming steps

Failure analysis of job insecurity diesel generator starting

After the diesel generator starting job insecurity Failure Analysis:After cranking speed diesel generator fluctuated, usually because the fuel adjustment system failure caused.Failure reason:1 each cylinder diesel generator work poor, leading to deflationary pressures are not the same for each cylinder.2 fuel supply system with air, water or poor oil supply.Associated with each cylinder plunger large … Continue reading Failure analysis of job insecurity diesel generator starting

How to calculate 7.5kw motor rated current

7.5KW three-phase motors (Y2 series) Rated current: 14.9 An (2-pole), 15.6 Ann (4-pole), 17.2 Ann (6-pole), 17.8 Ann (8-pole). No-load current is about 30 to 50% of the rated current.Calculation method:P = 0.85 * 1.732UI = 0.85 * 1.732 * 380 * II = 13.4 over the algorithm 7.5kw three-phase asynchronous motors. 0.85 power factor.

What is the difference between circuit and magnetic circuit

What is a circuit?EMF (voltage) under the path of the currents flowing through the circuit. Usually consists of a power supply, load and switch it into three parts. The magnitude and direction of the current flowing through the circuit the circuit does not change with time, called the DC circuit. The magnitude and direction of … Continue reading What is the difference between circuit and magnetic circuit