❤【Introduction】- OP320-A is a small man-machine interface, mainly used with various kinds of PLC (or intelligent controller with communication port) ❤【Function】- Communication protocol and screen data are downloaded to the display without PLC writing communication program. It has password protection, has alarm list function, line by line real-time display current alarm information. With background light … Continue reading OP320 – A 3.7 inch Text Display HMI Support S485/RS232 Communication Port Mainly Used with PLC
Tag: op320
Omron PLC and text display op320 how to connect
Select the PLC below the file in OP320, you can see there are different types of PLC omron good need to set the corresponding parameters in it, you can download.
Text op320-a how to display mitsubishi PLC program inside the count
The general method is: mov instruction. For example: LD M8000 MOV C10 D2 Then use the text to monitor the value of D2. Since it seems that some text can't display the current value of C or T directly, it becomes a habit later that all C and T are replaced by D, and it … Continue reading Text op320-a how to display mitsubishi PLC program inside the count
Is the font size of op320-a /OP325 fixed and cannot be modified? How do I shrink the font?
The edit menu on the right has a vector text that you can click on to resize the text.
Text op320 does not download into the program
The serial port that comes with the computer tries serial port if can the problem still is on the line
How to set the OP320 text display to change PLC register data.
Click on a register widget and there is a Settings data in it
What programming cable will be used for the OP320 text display
Unlike the universal RS232, the universal RS232 is (2,3,5) to (3,2,5), and the cable has to be connected to seven corners at each end. The correspondence is (2,3,5,7) to (3,2,5,7).
Op320 program download go in press the button did not respond for a while the display is communicating
The reasons for op320 version 6.5z are as follows: 1: communication with slave station (PLC or instrument) is interrupted, it is always in the connected state, it cannot carry out other operations, the key will not work. 2: configuration from the station PLC or register address error, cannot read correctly, the results as above!
Can the text display of the xinjie op320 be uploaded?
No, it can only be downloaded.
How to use the text of Xinjie op320-A, how to control the PLC
The text is very simple, just like the touch screen, but it is much simpler than the touch screen. You can operate the PLC bit software by pressing the button, such as M S X Y, etc. Data input and data display are also available.