Timed extension of FX series PLC programming

FX series timers for a maximum time of 3 276.7s, if you need more time, you can use the circuit shown in Figure 1. When OFF is X2, T0, and C0 is in reset State, they do not work. X2 for ON Shi, its often open touch points connected, T0 began timing, 3000s Hou 100ms … Continue reading Timed extension of FX series PLC programming

PLC program instructions FEDND

Instruction FEND number main program ends FNC06, no operation, taking up 1 program step. FEND main program ends, as when performing to FEND, PLC input/output processing, watchdog timer, refresh, complete and return the start step.FEND instruction should be used note:1) subroutines and interrupts service routines should be placed after the FEND;2) subroutines and interrupts service … Continue reading PLC program instructions FEDND

PLC subroutine call and return instructions

CALL subroutine call instruction's number is FNC01. P0~P127 the operands, this instruction takes 3-program step.SRET subroutine return directive number FNC02. No operands, occupies 1 program step.As shown in Figure 1, if X0 connected, go to the label P10 to execute subroutines. When a SRET instruction is executed, it returns to the next step of the … Continue reading PLC subroutine call and return instructions

FX2Nc series PLC performance profile (basic unit, extension)

FX2NC has very high performance volume and communication capabilities, can be installed to a PLC in a much smaller space than standard. I/O connectors wiring costs can be reduced, saving connection time. I/O point numbers can be extended to 256, optional real-time clock, can connect up to 4 specific modules. Take advantage of built-in features, … Continue reading FX2Nc series PLC performance profile (basic unit, extension)

Mitsubishi PLC ladder diagram and the SFC by for example

When you use a step ladder instruction programming, first to design a State transition diagram based on State transition diagrams into a step ladder or instruction sheet. These three types of representation is shown in Figure 5-2. Action process when stepping contact S20 is closed, Y1 coil output relays switched on. When closing X0 a … Continue reading Mitsubishi PLC ladder diagram and the SFC by for example

PLC program design

PLC programming is generally divided into the following steps:1. programming preparationsGetting ready for a program is to understand the whole control system functionality, scale, control, input/output signals of type and quantity, special features of the interface and the relationship with the other device, contents and methods of communication, the entire concept of the control system … Continue reading PLC program design