(1) each counter has a 32-bit high-speed current values of preset and a 32-bit value, current value, and default value for the signed integer values. To set the new high speed counter current and new preset values, you must set the control byte (table 6-7), making it the fifth and sixth bit is 1, allow … Continue reading S7-200 PLC high speed counter instructions
Tag: plc basics
S7-200 PLC type of interrupt sources
S7-200 sets the interrupt function for real-time control, high-speed processing, communications and control of complex and special tasks such as network. Disruption is to terminate the currently running program, to carry out immediate interrupt service program has been developed in response to signals, is complete and then return terminated the program and continue to run.Interrupt … Continue reading S7-200 PLC type of interrupt sources
S7-200PLC structure
1. Status indicator (LED) displays the CPU's job status.SF--System Fault (System error)RUN--runSTOP--stop 2. Memory cards can be inserted memory card 3. Communication interface can be connected RS-485 communications cable_ EMBED PBrush ___ 4. Top cover bottom for output terminals and the PLC power supply terminal. Running from the top of the output terminal terminal block cover beneath a … Continue reading S7-200PLC structure
Siemens PLC interface module
S7-200 digital I/O module interface module, analog I/O modules and communication modules. These modules are introduced below.(A) the digital I/O moduleDigital I/O module is native integration to solve digital input/output points can not meet the need to use extension modules. S7-200PLC currently offers 3 categories in total, total 9 digital I/O module.1. EM221 digital input … Continue reading Siemens PLC interface module
Structure of the Siemens S7 PLC timer
S7 clock time by time and time value is composed of two parts, time is equal to the product of time and timing values. When the timer runs, the timing values continue to lose 1, until reduced to 0, down to 0 means that the time to. Time after time to cause the timer contacts.Timer … Continue reading Structure of the Siemens S7 PLC timer
Siemens PLC VS Panasonic PLC
1. Programming softwareSiemens SIMATIC PLC series offers a variety of programming software, mainly STEP MICRO/DOS and STEP MICRO/WIN;STEP mini standard package STEP7S7 PLC programming language is very rich, includes LAD, and STL, SCL, GRAPH, HIGRAPH, CFC etc. Users can select a language, if required, can also be mixed using several programming languages.2. Program structureProgram structure … Continue reading Siemens PLC VS Panasonic PLC
Siemens PLC S7-200 addressing modes
Is the basic unit of S7-200 programming language statements, while a statement consisting of instructions, each instruction has two parts: one is the opcode, another part of the operands. Opcode is to point out what is the function of this instruction, operand specified opcode contains the data needed. So-called addressing, is the process of looking … Continue reading Siemens PLC S7-200 addressing modes
PROFIBUS,PROFINET,Ethernet differences
Simply said, PROFINET=PROFIbus+etherNET, ported to Profibus master/slave structure on Ethernet, PROFINET Controller and Device, they can simply corresponds to the PROFIBUS Master and Slave, of course, there is a difference, but it can help you understand. In addition because of Ethernet based PROFINET is, you can have an Ethernet star, tree, bus type, such as … Continue reading PROFIBUS,PROFINET,Ethernet differences
What is Siemens Siemens system PROFIBUS DP or PROFINET IO
PROFIBUS DP is an open bus system, in line with the standard IEC 61784-1:2002 Ed1 CP 3/1, using the Transport Protocol "DP" (DP is the German term "dezentrale Peripherie" [distributed I/O] abbreviation).Physically, the PROFIBUS DP is based on unshielded cable (RS 485) electrical network or based on fiber-optic cable (FOC) optical networks.Transfer Protocol "DP" to … Continue reading What is Siemens Siemens system PROFIBUS DP or PROFINET IO
Siemens S7-300PLC tissue piece OB and OB10
OB10 can be run according to the following intervals:Once (once): only once at a specific date and time. String 7Every minute: starting from a specific date and time, once per minute. String 9Hourly: starting from a specific date and time, once per hour.Daily: starting from a specific date and time, once a day.Weekly: starting from … Continue reading Siemens S7-300PLC tissue piece OB and OB10