PLC connection relay

Can both control and manual control, auto/manual transfer switch should be added, in case of contradiction between automatic and manual control, and automatic/manual transfer switch, then you can completely from the PLC, relay direct control of solenoid valves achieve the purpose of manual

PLC selection guide

First, input/output (I/O) point estimateI/O points should be considered when estimating the appropriate margins, usually according to the statistics of the input and output points, adding 10%~20% and ExtensibleAfter allowance, as input and output point estimates. Actual orders, according to manufacturer product features of the PLC, the input and output points are rounded.Second, the storage … Continue reading PLC selection guide

PLC-contact (OR/ORI) Instructions Use for example

OR (or) normally open contacts connected in parallel directivesORI (or not) normally closed contacts connected in parallel directivesIntroductions:(1) OR ORI is connected in parallel to a single point of contact and instructions, paralleling a plurality of contacts cannot be used with this directive(2) and ORI OR directive from which the current step, LD, LDI instruction … Continue reading PLC-contact (OR/ORI) Instructions Use for example

PLC-contact instructions (FNC224~FNC246)

Contact compare total 18(1) the LD contacts compare this kind of instruction mnemonics, code, and functionality.(2) compare AND contact the class instruction mnemonic, code(3) OR contact instructionsOR= instructions for use as shown in Figure 3-93, when X1 is ON, or the current value of the counter is 200, driving Y0.Contact compare any data format of … Continue reading PLC-contact instructions (FNC224~FNC246)

PLC gray code conversion and analog module special instructions

(1) gray code transform and inverse transform instructions these instructions 2: GRY (FNC170) and GBIN (FNC171), used for photoelectric encoder encoder disk data. (D) GRN (p) instruction function is to convert binary to gray code, (d) GBIN (p) instruction is the inverse transform of GRY. As shown in Figure 3-89, GRY command is the source … Continue reading PLC gray code conversion and analog module special instructions

PLC Clock operation Instructions (FNC160~FNC169)

Seven clock operation class instruction, Directive number distribution between FNC160~FNC169. Such instructions are on the clock clock operation operation and compare the data, PLC built-in real-time clock for time calibration and data formatting.(1) clock and data compare TCMP (FNC160) TCMP (p) function is used to compare the data in the specified time and clock size. … Continue reading PLC Clock operation Instructions (FNC160~FNC169)