Delay interrupt OB 20- Siemens S7-300 PLC organization block OB

By calling the SFC 32 starts. SFC 32 o'clock to provide arguments is called.OB-NR delay interrupt OB numbersDTIME delay length (1 to 60000ms)SIGN extended into OB OB called startup information signsRET-VAL OB the error code if an error occurs during the execution ofDelay interrupts SFCSFC32 SRT_TINT start delay interruptsSFC33 CAN_DINT cancel delay interruptsSFC34 QRY_TINT query … Continue reading Delay interrupt OB 20- Siemens S7-300 PLC organization block OB

Day interrupt (OB10) – Siemens S7-300 PLC organization block OB

OB10 can be run according to the following intervals:Once (once): only once at a specific date and time.Every minute: starting from a specific date and time, once per minute.Hourly: starting from a specific date and time, once per hour.Daily: starting from a specific date and time, once a day.Weekly: starting from a specific date and … Continue reading Day interrupt (OB10) – Siemens S7-300 PLC organization block OB

Normally closed contact Input signal Processing circuit and PLC ladder diagram

In these input signals can only be provided by a normally closed contact, Figure 1a is to control the motor run relay circuit, SB1 and SB2 start button and stop button, respectively, if they are normally open contacts connected to PLC input, type contacts in the ladder diagram with exactly the same figure 1a. If … Continue reading Normally closed contact Input signal Processing circuit and PLC ladder diagram

PLC programming elements timer

Timer is equivalent to relay time relay in the circuit may delay control in your program. FX2 series programmable controller has the following four types of timer.100ms timer: T0~T199 200 timing ranges: 0.1~3276.7 sT200~T245 46 10ms timer timing range: 0.01~327.67 s1ms totalizer timers T246~T249 4 (interrupt) time range 0.001~32.767 s100ms totalizer timer T250~T255 6 timer … Continue reading PLC programming elements timer

Mitsubishi FX2N PLC instructions- four-storey elevator control system

1~4 the stairs outside the request button, FU, FD;1~4 floor SQ1~SQ4 floor signals;In the boot button on the control panel signals;Elevator door opening and closing limit switch.Output signal:Lifting light,Elevator lift AC contactor KM1~KM2,Elevator door AC contactor KM3~KM4,The Bell.1. upon the request 1-4 outside staircase and elevator operation status timely response:Increase process, floor upstairs along the … Continue reading Mitsubishi FX2N PLC instructions- four-storey elevator control system