how to install gx developer

1, Download GX Developer 8.86 2, enter the registry, delete HKEY_CURRENT_USER\Software\MITSUBISHI HKEY_LOCAL_MACHINE\SOFTWARE\MITSUBISHI 3, the installation package should be located in the D disk, unpack the file to the "886" folder 4, close all antivirus software, firewall these two software will affect the installation process of reading and writing files, first shut down the best 5, … Continue reading how to install gx developer

OYES PLC applied using a small wave soldering machine design

I. OverviewUsually large wave soldering machines, production lines, but some customers such as laboratories, schools, small factories need a small lead-free wave soldering machine. Certain electronic equipment factory developed this product, using the Austrian letter OYES series PLC and touch screen. The device requires three temperature control, a total of three PID, the Austrian letter … Continue reading OYES PLC applied using a small wave soldering machine design

S7-200 addressing method in PLC programming

       In the S7-200 series, addressing modes are divided into two kinds: direct addressing, and indirection. Direct addressing mode is used directly in the instruction memory or registers the component name and address number, direct to find the data. Indirect addressing is the address pointer is used to access data in the memory, before use, … Continue reading S7-200 addressing method in PLC programming

WinCC Siemens S7 300 and 400 PLC OPC configuration

1. Configuration software:  1. SIMATIC STEP 7 5.42. SIMATIC NET 5.43. SIMATIC STEP 7 SIMATIC NET and 5.4 5.4 authorizationInstallation of SIMATIC STEP 7 SIMATIC NET and 5.4 5.4II. Configure the OPC STATION1. open the STEP 7 softwareFigure 12. Insert a SIMATIC PC StationFigure 23. renamed "PC2"Figure 34. configuration of SIMATIC PC STATIONG, double-click the "configuration"Figure … Continue reading WinCC Siemens S7 300 and 400 PLC OPC configuration

Siemens S7-300/400 PLC Closed-loop control module

1, FM 355 closed-loop control module FM 355 closed-loop control channel 4, used for pressure, flow, liquid level control, optimum temperature control and PID algorithms. FM 355C analog output is 4 fracture of continuous controller, FM 355 s is 8 digital output point step controllers or pulse. CPU FM 355 people after a disruption or failure … Continue reading Siemens S7-300/400 PLC Closed-loop control module

Siemens 200 PLC analog input/output

Analog input/output universal conversion formula you can use the following conversion:Ov = [(Osh - Osl)*(Iv - Isl)/(Ish - Isl)] + OslOf which:Ov: conversion resultsIv: conversion objectsOsh: conversion result limitOsl: conversion results lower limitIsh: conversion limitIsl: conversion of lower limitSTEP 7-Micro/WIN Programming Tips (Micro/WIN programming skills) Tip38 about how to achieve the conversion routines.For convenience of … Continue reading Siemens 200 PLC analog input/output

Siemens PLC analog module usage questions

S7-200 analog input module (EM231,EM235) addressingEach analog expansion module, sorted by extension modules in the order, in which the analog input and output according to different sorting, respectively. Analog data format is one word, so the address must begin with an even number of bytes, precision 12-bit; analog values with the value 0-32000. Input format: … Continue reading Siemens PLC analog module usage questions